Page 11For technical questions, please call 1-800-444-3353.SKU 68018
parts. If any problems are found,
do not use tool until repaired.
Testing the Single Sequential Safety
Trip Mechanism
Even though the
Stapler should be
empty during this procedure, ALWAYS
point the Stapler at a piece of scrap
wood when testing.
1. Make sure the tool is disconnected from
the power supply.
2. Completely empty the magazine
of staples.
3. The Stapler should not re if the nose is
not depressed against the workpiece.
4. Check that the Trigger (32) and
the Safety Tip (38) move freely,
without sticking.
5. Connect the air supply to the tool
at the Air Inlet Plug (72) set at the
recommended 60-120 PSI, and not to go
over the maximum 120 PSI.
6. Test the tool by depressing the Safety
Tip against the workpiece without
pulling the Trigger. The tool must
not cycle (re). If it cycles (res),
stop immediately and take the tool to a
qualied service technician.
7. Hold the tool away or off of the
workpiece. The Safety of the tool
should return to its original position.
Squeeze the Trigger. The tool should
not cycle (re). If it cycles (res),
stop immediately and take the tool to a
qualied service technician.
8. Depress the Safety Tip against the
workpiece and squeeze the Trigger.
The tool must cycle (re) once only.
Release the trigger and squeeze it again.
The tool must cycle (re) once only.
With the Trigger held, carefully lift the
nailer and press it against the workpiece
again. The tool must not cycle (re).
If it fails to act in the manner explained
in bold, have it repaired by a qualied
service technician.
Loading Staples
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL OPERATION,
BEFORE LOADING:
Wear ANSI-approved safety
goggles with side shields. Other
people in the work area must also
wear ANSI-approved impact safety
goggles with side shields.
Release the Trigger.
Detach the air supply.
Attempt to re the Tool into a
piece of scrap wood to ensure
that it is disconnected and is
incapable of ring any fasteners.
1. Press down on the Latch (63) and pull
back on Nail Guide Frame (51).
2. Insert a row of clean, undamaged
staples onto the Pusher (50).
3. Push Nail Guide Frame forward until
Latch snaps into place in Magazine (49).
General Operating Instructions
1. Test the Tool, as directed in the prior
section, before each use.
2. If automatic oiler is not used, add a few
drops of Pneumatic Tool Oil into the air
inlet plug connection before use. Add
a few drops more after each hour of
continual use.
3. Attach the Stapler to the air supply at the
Air Inlet Plug. Start your compressor and
check the pressure, making sure it is set
at the recommended 60-120 PSI and not
to go over the maximum 120 PSI.